Daikin Service Checker Type 3 Download

Daikin Service Checker Type 3 DownloadDaikin Service Checker Type 3 Download

• i30-408 Basic Training Manual. • VRV system. We wish that you would use this manual as a guidebook for the service of VRV system or as a reference book for education of service personnel, which leads to the development of skills in whole service group of Daikin. • Si30-408 General Contents General Contents General Contents General Contents A.

Octave One The Collective Raritan on this page. Global webcast auction u.s. Paper converters, inc. - major paper converting auction, featuring: dual rotary knife sheeters, slitter-rewinders, unwind stands. View and Download Daikin SM-12-012 service manual online. SM-12-012 Air Conditioner pdf manual download.

Introduction..1 B. Basic Information..21 C.

Field Settings from Remote Controller.41 D. Cases for Examination..109 F. Service Checker Type3 Application Edition.127 G. • Si30-408 General Contents.

Introduction A. Introduction A. Introduction 1. What is a VRV System?..2 2.

List of VRV Unit Models..3 2.1 List of Outdoor Unit Models..3 2.2 Nomenclature...5 3. System Basic Configuration..11 3.1 Cooling / Heating Selection -Standard- System.11 3.2 Heat Recovery (Cooling / Heating Individual Operating) System.14. • What is a VRV System? What is a VRV System?

VRV System Thirty or more indoor units can be connected to single system. There are 'cooling / heating selection -standard- type' and 'individual operating system of cooling and heating' according to type of the system. List of VRV Unit Models List of Outdoor Unit Models Type R22 C to H series R22 K series VRV Standard C series VRV for High outdoor temp (with unloader comp.) Model Type Service manual Model Type Service manual —.

• VRV Inverter K series Model Type Service manual RSXYP5-10KJY1 Heat-pump Si-90A RSXP5-10KY1 Cooling only Si33-106 VRV Inverter K series (H/R with Scroll Comp.) Model Type Service manual RSEYP8, 10KJY1 Heat- Si-96 Recovery VRV High COP type L series Model Type. • Si30-408 List of VRV Unit Models Nomenclature 2.2.1 Nomenclature (Previous indication) Indoor Unit Power supply symbol V1: Single phase 220 to 240V, 50Hz VE: Single phase 220 to 240V, 50Hz: 220V, 60Hz VAL: Single phase 220V, 60Hz. • List of VRV Unit Models Si30-408 Indoor Unit Power supply symbol V1: Single phase 220 to 240V, 50Hz Indicates major design category B: New ceiling suspended cassette K: Wall mounted type 40-63 Capacity Indication Conversion to horsepower: 40: 1.6HP 50: 2.0HP. • Si30-408 List of VRV Unit Models Connection Unit (Only Necessary for FUYP Indoor Units) Power supply symbol VE: Single phase 220 to 240V, 50Hz: 220V, 60Hz Indicates major design category Capacity Indication Conversion to horsepower: 71: 3HP.

• List of VRV Unit Models Si30-408 Outdoor Unit (Combination Model Name) The unit with anti-corrosion treatment Power supply symbol Y1: 3 phase 380 to 415V, 50Hz TAL: 3 phase 220V, 60Hz YAL: 3 phase 380V, 60Hz Indicates major design category. • N: Concealed floor standing type D: Slim ceiling mounted duct type U: Ceiling suspended cassette type (Connection unit series) Indicates that this is VRV system indoor unit. (V2286) BS Unit (Only Necessary for Heat Recovery System) V1: Single phase 220 to 240V, 50Hz.

• List of VRV Unit Models Si30-408 Outdoor Unit B: The unit is for European Standards E: Unit with anti corrosion treatment Power supply symbol Y1: 3 phase 380 to 415V, 50Hz YL: 3 phase 380V 60Hz. • Si30-408 System Basic Configuration 3. System Basic Configuration Cooling / Heating Selection -Standard- System 3.1.1 Type A R(S)XY(P) ~ Outdoor unit • Controls operation mode by using four way valve R22 / R407C • Changing of outdoor heat exchanger to condenser or evaporator Two pieces of piping for liquid and gas Cooling Mode. • System Basic Configuration Si30-408 3.1.2 Type B BL 2 ~ 3K (A): Functional unit RXY ~ K (A): Inverter unit RNY ~ K (A): STD unit Functional unit STD unit Inverter unit Enter to functional unit Among outdoor units: three pieces of piping for liquid, from each outdoor unit. • • Changing of outdoor heat exchanger to condenser or evaporator Three pieces of piping for liquid, gas, and oil equalizer Oil equalizer is installed only when outdoor VRV system is connected. Cooling Mode Cooling Mode Normal motorized valve (SH) control. • System Basic Configuration Si30-408 Heat Recovery (Cooling / Heating Individual Operating) System R(S)EYP(Q) ~ Outdoor unit • Control operation mode by using plural four way valves • Outdoor heat exchanger is divided and changed to condenser / evaporator based on the load R22 / R407C / R410A BS unit.

• Si30-408 Super Wiring System 4. Super Wiring System Points of Super Wiring System Power supply 3-phase, 220 V Outdoor unit Outdoor unit or 380 ~ 415 V (Master unit) (Slave unit) A B C Point Cooling / heating selection All control wires shall be of remote controller Power supply no polarity and two core type.